Closed-end connectors are used where a few wires must be joined and finished in one spot, such as in light fittings, junction boxes and appliances. They look like small caps, closed at one end, so the wires go in from one direction only. Crimping the inner metal sleeve grips the wires together, and the outer body covers and protects the joint. Based on the Allpum closed-end connector (APWP) range, here is how to choose a size, the crimping sequence and how to check the result.
How a closed-end connector is built and where it is used
A closed-end connector consists of an outer insulating body and an inner metal sleeve. The wires go into the wide entry, and the narrow section holding the metal sleeve is pressed with a tool to make the crimp. Because the end is closed, the wire tips are not exposed. Allpum closed-end connectors have a white PE (polyethylene) body and are intended for joining wire ends and protecting the joint. Unlike twist-on wire connectors, a crimp cannot be undone, so they suit permanent joints rather than places that must be reopened later.

Choosing a size: the gathered wires must fit the entry diameter
The size depends on the wire gauge and the number of wires. The key is that the gathered wires go into the entry diameter (A) without being forced, and do not rattle once inside. Too small and the wires will not go all the way in or strands will bend; too large and the sleeve cannot grip the wires properly even after crimping. Check the applicable wire range (AWG and SQ) for each item in the specification table on the product page, and when you are on the borderline, test-fit the actual wires before choosing.
| Item | Entry Ø A (mm) | Outer Ø B (mm) | Height C (mm) | Packing (pcs/bag · bags/box) |
|---|---|---|---|---|
| APWP-1.5 | 2.5 | 8.2 | 17 | 1,000 · 50 |
| APWP-2.5 | 3.0 | 8.8 | 21 | 1,000 · 35 |
| APWP-4.0 | 4.0 | 9.3 | 18.2 | 1,000 · 35 |
| APWP-6.0 | 4.5 | 11.1 | 19.2 | 1,000 · 25 |
| APWP-8.0 | 5.3 | 11.7 | 20.4 | 1,000 · 20 |
Crimping step by step
- 1. Isolate the power Switch off the circuit and confirm it is dead before you begin.
- 2. Strip the insulation Strip to the depth of the metal sleeve. Too short and insulation ends up under the crimp; too long and bare conductor shows outside the entry. Use a suitable stripper so the strands are not nicked.
- 3. Gather the wires Line up the stripped ends side by side. For stranded wire, give the strands a light twist so they do not splay.
- 4. Insert fully Push the wires in until the tips reach the closed end. Make sure no single wire is short of the others.
- 5. Crimp in one go With a crimping tool suited to insulated connectors, centre the narrow sleeve section in the jaw and squeeze until the tool closes fully. Squashing it with pliers does not give an even crimp.
- 6. Pull test Pull each wire by hand to check it does not come out. If one slips or feels loose, cut it off and redo it with a new connector.
A good crimp and one that needs redoing
| Check | Good | Redo |
|---|---|---|
| Entry | Insulation reaches inside the entry; no bare conductor visible | Bare copper visible outside the entry |
| Crimp position | The middle of the narrow sleeve section is pressed | Only the wide entry body is pressed, or the crimp is off to one side |
| Body | Intact, without splits or holes | Body split or sleeve poking through |
| Wires | Every wire holds when pulled | Any wire pulls out or turns |
Points to watch
- Single use A crimped connector is not reopened and reused. If the joint must be remade, cut it off and use a new one.
- Use another method where joints are reopened For joints that are opened often during maintenance, a removable method such as wire connectors or lever connectors is easier.
- Match the wires Mixing very different gauges in one connector tends to leave the thinner wire under-gripped. Pull-test every joint.
- Check the circuit Follow the design basis and applicable rules for the current and environment of the circuit, and consider another jointing method where needed.